WEKO3
アイテム
室内回流式温度成層風洞の基本性能及び夏季晴天時の公園緑地の熱環境シミュレーション
https://kougei.repo.nii.ac.jp/records/377
https://kougei.repo.nii.ac.jp/records/377b7b8d38f-52ff-4454-837e-fc8b3fccc59e
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | [ELS]紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-04-21 | |||||
タイトル | ||||||
タイトル | 室内回流式温度成層風洞の基本性能及び夏季晴天時の公園緑地の熱環境シミュレーション | |||||
タイトル | ||||||
タイトル | A Performance of Thermally Stratified Closed-type Wind Tunnel and Simulation of Thermal Environment in parks and Green Belts in Summer | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00159741 | |||||
論文名よみ | ||||||
タイトル | シツナイ カイリュウシキ オンドセイソウ フウドウ ノ キホンセイノウ オヨビ カキ セイテンジ ノ コウエン リョクチ ノ ネツカンキョウ シミュレーション | |||||
著者 |
大場, 正昭
× 大場, 正昭× 栗田, 剛× 名和, 健太郎× Ohba, Masaaki× Kurita, Tsuyoshi× Nawa, Kentaro |
|||||
著者所属(日) | ||||||
東京工芸大学工学部建築学科 | ||||||
著者所属(日) | ||||||
株式会社風技術センター | ||||||
著者所属(日) | ||||||
東京工芸大学大学院工学研究科建築学専攻 | ||||||
記事種別(日) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 論文 | |||||
記事種別(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | A new wind tunnel has been designed to study the effects of thermal stratification on flow and diffusion in an urban area. Its operating performance was much better than that of previous systems due to newly designed temperature control systems composed of a re-heater and floor heating panels. The wind tunnel could create temperature gradients as strong as a bulk Richardson number equivalent to 0.57 and maintained stable layers in the test section. The thermal boundary layer in summer was developed by using the heating panels. The cooling panel with cold water simulated the cool surface zone in parks and green belts. When the cooling panel was set to the leeward of the heating panel, a large cooled air resion was generated on the cooling panel. It is expected that by simulating nocturnal cold air drainages occurred by the surface temperatures differences between parks and built-up areas, appropriate methods could be developed to keep the urban climate more comfortable in summer. | |||||
書誌情報 |
東京工芸大学工学部紀要 en : The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University 巻 24, 号 1, p. 39-47, 発行日 2001 |
|||||
表示順 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 8 | |||||
アクセション番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | KJ00000124179 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03876055 |