{"created":"2023-06-20T13:23:07.961156+00:00","id":46,"links":{},"metadata":{"_buckets":{"deposit":"28f839a6-7a3c-485f-b828-1d25daea1bf3"},"_deposit":{"created_by":3,"id":"46","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"46"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000046","sets":["12:17:24:25"]},"author_link":["74","96","73","3235"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1980","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"50","bibliographicPageStart":"43","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Strict similarity for the prediction of velocity and temperature distributions in an airconditioned room requires the equalities of both the Reynolds number and Archimedes number in both model and prototype. In actual model experiment, however, it is very difficult to satisfy these strict similarity requirements. In the present paper, a minimum Reynolds number is suggested above which it is possible to neglect the Reynolds number from the strict similaritv requirements without considerable error. This minimum Reynolds number was determined by measuring velocity distributions and observing the air now patterns in three geometrically similar models and found to be about 7000, within the limits of the experiment.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"7","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00001511865","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Architecture, Faculty of Engineering, Tokyo Institute of polytechnics"},{"subitem_text_language":"en","subitem_text_value":"Tokyo Institute of Polytechnics"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"Minimum Reynolds Number for the Relaxation of Similarity Requirements for Predicting Room Air Distribution"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 信行"},{"creatorName":"コバヤシ, ノブユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"96","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUBARA, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"3235","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KOBAYASHI, Nobuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"73","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUBARA, Yukio","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"74","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00001511865.pdf","filesize":[{"value":"595.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00001511865.pdf","url":"https://kougei.repo.nii.ac.jp/record/46/files/KJ00001511865.pdf"},"version_id":"96a043f6-0bf9-4bf6-804f-8454ff63b942"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Minimum Reynolds Number for the Relaxation of Similarity Requirements for Predicting Room Air Distribution","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Minimum Reynolds Number for the Relaxation of Similarity Requirements for Predicting Room Air Distribution","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["25"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"46","relation_version_is_last":true,"title":["Minimum Reynolds Number for the Relaxation of Similarity Requirements for Predicting Room Air Distribution"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T13:46:08.709244+00:00"}