{"created":"2023-06-20T13:23:30.635586+00:00","id":378,"links":{},"metadata":{"_buckets":{"deposit":"43a318bd-d2e8-48ce-9eac-e3c7c11f7d1c"},"_deposit":{"created_by":3,"id":"378","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"378"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000378","sets":["12:17:66:67"]},"author_link":["3054","556","925","555"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"55","bibliographicPageStart":"48","bibliographicVolumeNumber":"24","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"MPPT (maximum power point tracking) control is very important Ror the practical PV (photovoltaic) systems to maintain efficient power generating conditions irrespective of the deviation in the PV array insolation or/and temperature conditions Although a plenty of researches have been done so far, most of them are too costly because of much dependence on expensive sensors for measuring photovoltalc power and micro-processors for achieving elaborate and comphcated control strategies From this point of view, authors have been researching on sensor-less approaches for MPPT control, and have proposed two types of new control schemes \"Power Equilibrium Scheme\" and \"Limit Cycle Scheme\" This paper summarises these two schemes with focussing on their operating principles and some results of simulation and experiments","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"9","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00000124180","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Dept of Electoronics and Computer Engineering, Faculty of Engineering, Tokyo Institute of Poytechnics"},{"subitem_text_language":"en","subitem_text_value":"Ph D candidate Graduate School of Electronics and Computer Engineering, Tokyo Institute of Polytechnics"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"Novel Photovoltaic Systems with Power Sensor-less MPPT Approaches for AC Mains Interface"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松井, 幹彦"},{"creatorName":"マツイ, ミキヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"555","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北野, 達也"},{"creatorName":"キタノ, タツヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"3054","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUI, Mikihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KITANO, Tatsuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"925","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00000124180.pdf","filesize":[{"value":"577.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00000124180.pdf","url":"https://kougei.repo.nii.ac.jp/record/378/files/KJ00000124180.pdf"},"version_id":"773a8d3b-64a0-447a-a771-808156757616"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Novel Photovoltaic Systems with Power Sensor-less MPPT Approaches for AC Mains Interface","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Novel Photovoltaic Systems with Power Sensor-less MPPT Approaches for AC Mains Interface","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["67"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"378","relation_version_is_last":true,"title":["Novel Photovoltaic Systems with Power Sensor-less MPPT Approaches for AC Mains Interface"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T13:44:33.854031+00:00"}