{"created":"2023-06-20T13:23:22.041492+00:00","id":260,"links":{},"metadata":{"_buckets":{"deposit":"6a9fbf0e-55da-4b60-adee-7db963eb7a69"},"_deposit":{"created_by":3,"id":"260","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"260"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000260","sets":["12:17:52:53"]},"author_link":["692","693","695","696","694","691"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"94","bibliographicPageStart":"87","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The parallel resonant link high frequency power conversion technique based on PDM (pulse density modulation) control scheme is advantageous for realizing a light weight and low EMI (electromagnetic interference) converter due to its soft switching operation. In this kind of circuits, the design of LC tanks for resonant link and that of control loops to maintain the voltage equilibrium of the link are the most significant points in considering the transient responses. This paper presents a novel state-averaging analysis method suited for resonant type converters. By using this method, a high frequency parallel resonant link can be equivaleritly considered as a dc link, which makes the transient analysis and/or design of the system easier. The validity of the proposed modeling method is confirmed by some simulation and experimental results.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"12","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00001512035","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京工芸大学大学院電子工学専攻"},{"subitem_text_value":"東京工芸大学工学部電子工学科"},{"subitem_text_value":"東京工芸大学工学部電子工学科"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"ジョウタイヘイキンカ ニ モトヅク キョウシンガタコンバータ ノタメノ アタラシイ カトカイセキシュホウ"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"楊, 永霞"}],"nameIdentifiers":[{"nameIdentifier":"691","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"秋山, 季夫"},{"creatorName":"アキヤマ, トシオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"692","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松井, 幹彦"},{"creatorName":"マツイ, ミキヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"693","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"YANG, Yong-xia","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"694","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"AKIYAMA, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"695","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUI, Mikihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"696","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00001512035.pdf","filesize":[{"value":"562.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00001512035.pdf","url":"https://kougei.repo.nii.ac.jp/record/260/files/KJ00001512035.pdf"},"version_id":"d4acfb7e-7339-4080-9771-b0818d6d5a27"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"状態平均化に基づく共振形コンバータのための新しい過渡解析手法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"状態平均化に基づく共振形コンバータのための新しい過渡解析手法"},{"subitem_title":"A Novel Transient Analysis Mehtod for Resonant Converters Based on State-Averaging Technique","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["53"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"260","relation_version_is_last":true,"title":["状態平均化に基づく共振形コンバータのための新しい過渡解析手法"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T14:21:18.236745+00:00"}