{"created":"2023-06-20T13:23:21.719711+00:00","id":256,"links":{},"metadata":{"_buckets":{"deposit":"b2ee197c-31d1-4a03-abdf-c2e6de19b3eb"},"_deposit":{"created_by":3,"id":"256","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"256"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000256","sets":["12:17:52:53"]},"author_link":["676","673","677","674","675","678"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"51","bibliographicPageStart":"43","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Thermal environment in the atrium with a large movable top-light have been studied by measuring the temperature distributions and PMV for various air-conditioning conditions. These field measurements were conducted in summer, autumn and winter. In winter, the influence of the cold air penetration from the entrance on temperature condition were also examined. The temperature in the atrium was strongly influenced by the solar radiation in every season and the stagnant air layer with high temperature arose in the upper part of the atrium, especially in summer. When the top- light roof was opened, the stagnant thermal layer was removed and relatively comfortable condition was achieved in the atrium. Under the normal air-conditioning, thermal environment conditions in the occupied zone were shown as \"relatively warm\" in summer, \"neutral\" in autumn and \"neutral\" in winter by the measurement of PMV. In winter, the air temperature in the occupied zone dropped by 7 to 8℃ due to the cold air penetrated from the entrance while five people were passing through the entrance doors. Six minutes was nearly required to recover the level of the former comfortable indoor temperature.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"8","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00001512031","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京工芸大学工学部建築学科"},{"subitem_text_value":"東京工芸大学工学部建築学科"},{"subitem_text_value":"(株)フジタ技術研究所"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"アトリウム ノ オンネツカンキョウノ ジッソク : オオキナ トップライト オ モツ バアイ"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鯉渕, 健造"},{"creatorName":"コイブチ, ケンゾウ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"673","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林, 信行"},{"creatorName":"コバヤシ, ノブユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"674","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 幸彦"},{"creatorName":"タナカ, ユキヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"675","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KOIBUCHI, Kenzo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"676","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KOBAYASHI, Nobuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TANAKA, Yukihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"678","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00001512031.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00001512031.pdf","url":"https://kougei.repo.nii.ac.jp/record/256/files/KJ00001512031.pdf"},"version_id":"96afbfad-5d27-4aeb-a19c-9c5962bfdbab"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"アトリウムの温熱環境の実測 : 大きなトップライトをもつ場合","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"アトリウムの温熱環境の実測 : 大きなトップライトをもつ場合"},{"subitem_title":"FIELD MEASUREMENTS OF THERMAL ENVIRONMENT IN ATRIUM WITH A LARGE TOP-LIGHT","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["53"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"256","relation_version_is_last":true,"title":["アトリウムの温熱環境の実測 : 大きなトップライトをもつ場合"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T14:21:56.711089+00:00"}