{"created":"2023-06-20T13:23:19.007814+00:00","id":211,"links":{},"metadata":{"_buckets":{"deposit":"4dc751d8-d6af-4e21-ba3a-e8c16d5041fe"},"_deposit":{"created_by":3,"id":"211","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"211"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000211","sets":["12:17:46:47"]},"author_link":["556","555"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"112","bibliographicPageStart":"103","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The high-frequency distribution system is a concept in which the frequency of power distribution lines in buildings, factories or chemical plants is made higher than that of utility line up to about 500Hz-1kHz. ln such systems, very high-speed rotation of ac machines. reduction of transformers or LC filters both in size and weight and many other advantages can be expected. 0ne of the key technologies in realizing such systems is that what type of power frequency changer is applied for a main circuit to link the high-frequency and the utility lines. This paper first summerizes the results of investigation on power distribution equipments for recent buildings including so called inteligent ones previously carried out by authors to evaluate the scale and the usefulness of such systems. Some possible topologies for frequency changer are compared. lt is concluded that the high-frequency cycloconverter system previously proposed by the author is an attractive one in the sense of low circuit conduction losses at maximum load and low harmonic distortion of input current without multiplexing circuits.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"10","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00001511986","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京工芸大学工学部電子工学科"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"コウシュウハ ハイデン システム ト コレ ニ テキシタ シュウハスウヘンカンホウシキ : ビル・コウジョウ ナドノ ローカル500Hz ハイデン システム"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松井, 幹彦"},{"creatorName":"マツイ, ミキヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"555","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MATSUI, Mikihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00001511986.pdf","filesize":[{"value":"780.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00001511986.pdf","url":"https://kougei.repo.nii.ac.jp/record/211/files/KJ00001511986.pdf"},"version_id":"ba1fab3f-70d3-4ebb-b2ba-ddb9277c334b"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高周波配電システムとこれに適した周波数変換方式 : ビル・工場などのローカル500Hz配電システム","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高周波配電システムとこれに適した周波数変換方式 : ビル・工場などのローカル500Hz配電システム"},{"subitem_title":"High-Frequency Power Distribution System and Its Suitable Topology for Frequency Conversion : Local 500Hz Distribution System in Buildings and Factories","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["47"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"211","relation_version_is_last":true,"title":["高周波配電システムとこれに適した周波数変換方式 : ビル・工場などのローカル500Hz配電システム"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T14:22:47.825393+00:00"}