{"created":"2023-06-20T13:23:17.229979+00:00","id":184,"links":{},"metadata":{"_buckets":{"deposit":"73a08a2e-6a5f-4f6e-afe0-74228b4132a6"},"_deposit":{"created_by":3,"id":"184","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"184"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000184","sets":["12:17:42:43"]},"author_link":["474","473"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1990","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"30","bibliographicPageStart":"23","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"As building air intakes are usually set on the upper part of buildings, considerable air pollution would often occur if the contaminant gas is exhausted from short stacks on building roofs. Many investigators have proposed diffusion models of predicting concentrations near an isolated building so as to determine whether ambient air quality or health conditions are likely to be exceeded or not. This paper investigates the prediction accuracy of these model formulae using wind tunnel data. It is found that Halitsky's formula for estimating dilution near the building air intake appears to be low accurate if the distance between the roof vent and the building air intake is short.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"6","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00001725577","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京工芸大学工学部建築学科"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"フウドウ モケイジッケン ニ ヨル タテモノキンボウ ノ オセンガス ノウドヨソク ニ カンスル ケンキュウ : キオウ ノ カクサンモデル ノ ヨソクセイド ノ ケントウ"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大場, 正昭"},{"creatorName":"オオバ, マサアキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"473","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"OHBA, Masaaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"474","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00001725577.pdf","filesize":[{"value":"602.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00001725577.pdf","url":"https://kougei.repo.nii.ac.jp/record/184/files/KJ00001725577.pdf"},"version_id":"b542071e-da24-4449-8315-9f736786b61c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"風洞模型実験による建物近傍の汚染ガス濃度予測に関する研究 : 既往の拡散モデルの予測精度の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"風洞模型実験による建物近傍の汚染ガス濃度予測に関する研究 : 既往の拡散モデルの予測精度の検討"},{"subitem_title":"EXPERIMENTAL STUDIES FOR PREDICTING CONCENTRATIONS NEAR A BUILDING USING WIND TUNNEL TECHNIQUES : PREDICTION ACCURACY OF PROPOSED DIFFUSION MODELS","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["43"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"184","relation_version_is_last":true,"title":["風洞模型実験による建物近傍の汚染ガス濃度予測に関する研究 : 既往の拡散モデルの予測精度の検討"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T14:23:19.785084+00:00"}