{"created":"2023-06-20T13:23:12.663879+00:00","id":122,"links":{},"metadata":{"_buckets":{"deposit":"622d157b-7af7-483b-9f8a-80627a531182"},"_deposit":{"created_by":3,"id":"122","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"122"},"status":"published"},"_oai":{"id":"oai:kougei.repo.nii.ac.jp:00000122","sets":["12:17:34:35"]},"author_link":["283","282"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"38","bibliographicPageStart":"34","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"東京工芸大学工学部紀要"},{"bibliographic_title":"The Academic Reports, the Faculty of Engineering, Tokyo Polytechnic University","bibliographic_titleLang":"en"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The possibiliy of light scattering technique is analysed, when it is applled to the detection of a single small particle suspendid in a highly purified liquid. The scattering light form a liquid and the Photon distribution in the scattered light make difficult to observe the signal from a small particle. The experimental condition is derived under the assumption that the photon distribution from both a liquid and a particle can be well separated from that from only a liquid. For example, this condition gives the necessary minimum laser power for the experiment.","subitem_description_type":"Other"}]},"item_2_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"8","subitem_description_type":"Other"}]},"item_2_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00002353293","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"論文","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00159741","subitem_source_identifier_type":"NCID"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03876055","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京工芸大学工学部写真工学科"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"ヒカリサンラン ノ コウシスウブンプ ト エキタイナイ タンイツビリュウシ ノ ケンシュツ ジョウケン"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊藤, 進一"},{"creatorName":"イトウ, シンイチ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"282","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ITOH, Shn-ichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"283","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-21"}],"displaytype":"detail","filename":"KJ00002353293.pdf","filesize":[{"value":"345.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00002353293.pdf","url":"https://kougei.repo.nii.ac.jp/record/122/files/KJ00002353293.pdf"},"version_id":"364e68d1-a14a-465f-9ff2-46aa2f78e77e"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"光散乱の光子数分布と液体内単一微粒子の検出条件","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"光散乱の光子数分布と液体内単一微粒子の検出条件"},{"subitem_title":"Photon Distribution in Light Scattering and the Detection of a Single Small in a Liquid","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["35"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-21"},"publish_date":"2017-04-21","publish_status":"0","recid":"122","relation_version_is_last":true,"title":["光散乱の光子数分布と液体内単一微粒子の検出条件"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T14:24:32.599949+00:00"}